Electrical
inspection
& testing

Close your
compliance
loop

UK-wide

We fuse together technical excellence and innovative technology to deliver a seamless compliance experience.

  • Fully Accredited
  • NDT
  • 18th Edition qualified
  • UK-wide coverage
  • Fully insured

Electrical compliance. Delivered differently.

We combine technical expertise, innovative reporting technology and a proactive approach to electrical safety to keep your buildings safe, compliant and operational. From inspection and testing through to certified remedial works and energy efficiency improvements, we help you reduce risk, control costs and make smarter decisions about your electrical estate.

  • Electrical Installation Condition Reports

    Periodic inspection and testing of fixed electrical installations to BS 7671, supporting compliance with the Electricity at Work Regulations 1989. We visually inspect and test distribution boards, final circuits and protective devices, including earthing and bonding, insulation resistance, earth fault loop impedance and RCD operation. Every observation is coded C1, C2, C3 or FI and recorded against the board and circuit it relates to, with a clear overall outcome and a recommended date for the next inspection. Defects feed directly into prioritised remedial quotations, giving you a clear, auditable record of where action is needed first.

  • Portable Appliance Testing

    In-service inspection and testing of electrical equipment in line with the IET Code of Practice, using a risk-based approach to set test frequencies by equipment type and environment. Each item undergoes a formal visual inspection and, where required, combined testing including earth continuity, insulation resistance and polarity checks for Class I and Class II equipment. Every appliance is labelled and logged in a detailed asset register by site, location and description, with its test results and next due date. Failed items are identified, isolated and reported immediately, so unsafe equipment is quickly removed from use and replacements or repairs can be arranged.

  • Emergency Lighting

    Emergency lighting testing to BS 5266, including functional and full-duration testing. Our detailed failed asset register captures fitting components, including batteries, ballasts and lamps, mounting heights and technical specifications, enabling accurate remedial quotations and the selection of photometrically compliant replacement fittings.

  • Thermal Imaging

    Non-invasive thermographic inspections assess electrical distribution boards, switchgear and connections under normal operating loads, identifying abnormal temperature rises, high-resistance connections, thermal patterns associated with phase imbalances and potential component deterioration. Findings are documented in detailed thermal reports, including temperature measurements, severity assessments and prioritised recommendations to reduce fire risk, prevent unplanned failures and improve asset reliability.

  • Remedial Works

    Comprehensive electrical remedial services to rectify defects identified during inspection and testing, supporting compliance with the Electricity at Work Regulations 1989. All completed repairs are appropriately inspected, tested and certified, with documentation cross-referenced against the original EICR observations. This closes the compliance loop, provides a clear audit trail and ensures electrical safety records are maintained for insurance audits, statutory compliance and future inspections.

  • Mains Analysis & Energy Optimisation

    Detailed power quality monitoring at your incoming supply and main distribution, using logging analysers installed over a representative period under normal operating loads. We record voltage, current, power factor, harmonic distortion, phase imbalance, transients and maximum demand. That shows where energy is being wasted, where reactive power charges are building up and where equipment is under strain. The findings go into a clear technical report with prioritised recommendations, which may include voltage optimisation, power factor correction, load balancing or harmonic filtering. Each recommendation comes with estimated savings and payback, so you can invest where it will make the biggest difference to your energy costs and reliability.

  • EV Charging & Solar Energy

    Design, installation and maintenance of commercial and domestic EV charging, solar PV and battery storage, tailored to your electrical estate. Every project starts with a site survey and a load assessment, so your existing supply can take on new demand safely. We use load management or export limiting where needed, and handle the DNO applications. Installations are carried out to BS 7671 and the relevant IET Codes of Practice, using smart chargers that meet current regulations. Each system is fully tested, commissioned and certified, and handed over with clear documentation. We also offer ongoing maintenance to keep chargers, panels and batteries working at their best.

Know where every building stands

Estate intelligence turns certificates into one live register. You see which sites are compliant, what is due next and which remedial work is still open, without chasing paperwork.

  • One register for the whole portfolioEvery certificate, report and due date stored against the right site.
  • Renewals planned before they lapseWe schedule retests ahead of expiry, so nothing slips into overdue.
  • Remedials tracked to completionEach C1, C2 and FI observation stays open until it is fixed and signed off.
  • Energy savings you can seeMains analysis results logged for each site, with savings tracked once improvements are made.
  • Route to electrificationFeasibility study for EV, solar and battery storage.
  • Reports ready for boards and auditorsExport compliance by region, building type or test whenever you need it.
Your EstateUpdated today
148Sites
96%Compliant
11Due in 60 days
3Open remedials
SiteTestStatusNext due
Address 1LeedsEICRCompliantMar 2029
Address 2BristolEmergency lightingDue soon14 Nov
Address 3GlasgowEmergency lightingCompliantApr 2027
Address 4BirminghamThermal imagingC2 remedial openBooked 30 Oct
Address 5ManchesterMains analysisReport issuedReview Jun 2027
Address 6CardiffPATOverdueBooked 27 Oct
Example data shown for illustration.

How it works, step by step

From the first property list to the next renewal, you deal with one team and one register.

  1. Share your estate

    Send us your property list and any existing certificates. We build your compliance register and show you the gaps.

  2. Agree the programme

    We plan visits around occupants and access, with one fixed quote for the whole schedule.

  3. Test and certify

    Qualified engineers carry out each test and upload certificates to your register as visits are completed.

  4. Fix what we find

    Dangerous faults are made safe on the day. Other remedials are quoted, completed and re-certified.

  5. Stay ahead

    Retests are booked before certificates expire, so your estate stays compliant year after year.

Built for multi-site estates with any level of complexity

From a single office to a national portfolio, we plan testing around how your buildings trade, who works in them and when they can be accessed.

Offices and managed estates

Property managers, landlords and facilities teams running multi-tenant offices and business parks, tested out of hours.

Retail and leisure

Shops, retail parks, restaurants and gyms, with visits scheduled around trading hours so doors stay open.

Industrial and logistics

Warehouses, factories and distribution centres, including thermal surveys of high-load switchgear and mains analysis to find wasted energy.

Education, healthcare and residential

Schools, clinics, care homes and residential portfolios, with visits planned around term times, patients and residents.

What drives us

Three principles that define how we work and what our clients can always expect from us.

  • Technical excellence

    Our people are our greatest asset. The skill, experience and care of our engineers are what set Fused apart. That’s why technical competence is at the heart of everything we do. Our engineers are NVQ Level 3 qualified and trained to the latest BS 7671 Wiring Regulations. We invest in their continuous professional development so they stay at the forefront of electrical safety, industry standards and best practice. Every inspection is delivered with technical precision, professionalism and an uncompromising commitment to quality.

  • Innovative technology

    Innovation is at the heart of Fused. Our experienced technical team has worked tirelessly alongside software developers to design and build our own bespoke electrical compliance reporting technology. Developed by engineers, for engineers, our software 'Fuses' together technical expertise with intelligent digital workflows, delivering detailed inspection reports, photographic evidence and clear, actionable compliance information. We are immensely proud of what we have created. By developing our own technology, we can continually refine our systems, improve efficiency and deliver a faster, smarter and more transparent service for our clients.

  • Closed loop compliance

    An electrical inspection is only the beginning of the compliance journey. Much like a vehicle MOT, identifying defects is only part of the process - ensuring they are rectified is what truly matters. At Fused, we take our responsibility as your electrical compliance partner seriously. We provide a seamless transition from inspection and fault identification through to competitively priced remedial works, verification and certification. Our streamlined processes ensure defects are addressed efficiently, with every repair documented and cross-referenced to the original inspection report. This reduces electrical safety risks, limits ongoing liability and provides a clear, auditable record of compliance.

    We don't just identify the risks. We see the process through to compliance.

Got questions?

Frequently asked questions

Can't find what you're looking for? Contact us directly and we'll be happy to help.

EICR

How often does my property need an EICR?

Most commercial premises need an EICR every 5 years, and privately rented homes in England need one at least every 5 years too. Some uses need shorter intervals: industrial sites are typically every 3 years, and leisure sites such as swimming pools every year. If the last report recommends an earlier date, that date takes priority.

Is an EICR a legal requirement?

The Electricity at Work Regulations 1989 require employers and duty holders to keep electrical systems safe. A current EICR is the accepted way to show you have done that.

What happens if my EICR comes back unsatisfactory?

A report is unsatisfactory if it records any C1 (danger present), C2 (potentially dangerous) or FI (further investigation) observations. We make C1 faults safe on the day, then quote for the remaining remedial work. Once the work is done we issue the certificates you need to show the report is closed.

PAT testing

What if an item fails PAT testing?

If an item fails PAT testing, it will be taken out of service immediately to prevent any risk of electrical harm.

How often should PAT testing be carried out?

There is no fixed legal interval. Frequency depends on the type of equipment and where it is used, usually between 6 and 48 months. Heavy-use and construction site equipment needs testing more often than IT equipment in an office. We will recommend a schedule for each site.

Services & coverage

Do you work with commercial properties?

Yes, commercial estates are our main focus. We work with offices, retail, industrial and logistics sites, schools, healthcare and residential portfolios, from single buildings to national estates.

What areas do you cover?

Full UK coverage and Republic of Ireland.

Can you handle multi-site compliance programmes?

Yes. Send us your property list and we will build a compliance register, show you the gaps and plan one programme across every site, with one fixed quote and one point of contact.

Reporting & turnaround

How quickly can you turn around a report?

Certificates are uploaded to your register as visits are completed, usually within 48 hours. If anything dangerous is found, we tell you on the day.

What format are your reports in?

Certificates are issued as PDFs on the standard BS 7671 forms. Everything is also held in your estate intelligence register, where you can export compliance by site, region or test for boards, insurers and auditors.

Emergency lighting

How often does emergency lighting need to be tested?

BS 5266 calls for a short function test (a flick test) every month and a full-duration test, usually 3 hours, once a year. We record results fitting by fitting and replace failed batteries and lamps.

Thermal imaging

What does a thermal imaging survey involve?

An engineer scans your distribution boards and switchgear with a thermal camera while they are running under normal load. Hot spots reveal loose connections, overloaded circuits and failing components before they cause a breakdown or fire. Nothing is switched off, so there is no disruption.

Who needs a thermal imaging survey?

Any site where electrical failure would be costly, especially industrial, logistics, retail and data-heavy buildings. Many insurers require an annual survey as a condition of cover.

Remedial works

Do I have to use you for remedial work?

No. You are free to use any qualified contractor. If you choose us, we quote straight from the report, complete the work and submit required paperwork.

How quickly are dangerous faults fixed?

C1 faults are made safe on the day they are found. C2 and FI items are quoted promptly so you can meet your deadlines, including the 28 days landlords are given under the private rented sector regulations.

Mains analysis & energy

What does a mains analysis involve?

We connect a power quality analyser to your main incoming supply and record it while the site runs as normal. The data shows how much power you use and when, along with voltage levels, power factor, harmonics and any imbalance between phases. Nothing is switched off.

What do I get at the end?

A clear report of the inefficiencies and power quality issues we found, what is causing them and the options to fix them, with the expected energy saving for each so you can decide what to do next.

Get in touch

Tell us about your estate and what you need tested. We will reply within one working day with next steps and a quote.

We only use your details to reply to this enquiry.